2026-11-01: Two bad sticks of RAM
On 1 November 2026 a memory stick in the montreal-1 server failed and took the server down with it. The provider replaced it, and before reopening we found a second bad stick in the logs and reported it. Both were replaced, and the endpoint has served since. No data was lost.
What happened
| When (EST) | What |
|---|---|
| 2026-10-13 | We get the server. |
| 2026-10-22 | montreal-1 opens to customers. |
| 2026-11-01 22:06 | The first stick, DIMM_B5, logs errors it cannot correct. |
| 2026-11-01 23:07 | The server stops answering. |
| 2026-11-02 14:03 | The provider replaces B5. |
| 2026-11-02 16:22 | Before reopening, we find errors from a second stick, DIMM_B1, in the logs and report it to the provider. |
| 2026-11-03 00:41 | The provider replaces B1. Their hardware scan passes. |
| 2026-11-03 00:54 | The endpoint serves again. |
The endpoint was down 1,547 minutes in all, about 25 and three-quarter hours.
The cause
Two memory sticks in the server went bad. The hardware log named each one and said to replace it.
The same log recorded one error on a PCIe device at the moment of the first failure. The provider's hardware scan after the repair found no fault.
Your data
Before serving again we ran the storage system's built-in integrity checks:
-
Disk integrity check: 0 errors.
-
Object integrity check: 0 errors.
-
No restore from snapshot necessary
Lessons learned
A new server waits before it serves anyone
The first stick failed 20 days after we got the server and 11 days after it opened to customers. Every disk was tested before montreal-1 opened but the memory was not. montreal-1 opened in the weeks when new hardware is most likely to fail.
New Rule: From now on a new server runs under load for 30 days before it opens, and never fewer than 20, the age at which this one failed.
Every part of the server has a plan, not only the disks
Disks are the part that fails most in a storage server, so that is where the architectural thinking went. The memory had no such plan, and one stick was enough to stop it.
New Rule: Every new server now gets a map of every part that can fail (disks, memory, processors, power supplies, network, storage controller, boot drive), and for each one, what happens to customers and how long it takes to restore. The memory row now has a measured answer: about 26 hours from the first error to serving again.
Likelihood of a similar incident
Minimal, except on newly provisioned machines. That is why the lessons learned above matter.